Main equipment body current rises and temperature rises , fan current drops.
Reasons: (1) Feed is excessive and air duct is blocked by powder. (2) Pipeline exhaust is not [...]
Reasons: (1) Feed is excessive and air duct is blocked by powder. (2) Pipeline exhaust is not [...]
Reasons : (1)The blades of classifying wheel wears too seriously to make the classifying wheel lose its [...]
Reason: The reason exists inside the milling chamber. Stop the machine and open the grinding chamber , [...]
The reasons are: (1) Parts are not fastened; (2) Bottom screw cap is loose; (3) Main shaft [...]
Problem: triangle belt is loose Solving method: Tighten the triangle belt and adjust other components properly so [...]